Bulletins

SIEMENS CERT
08/09/2022
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for …
SIEMENS CERT
08/09/2022
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 …
SIEMENS CERT
08/09/2022
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
07/12/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
07/12/2022
Siemens has released updates for Opcenter Quality to fix an authentication bypass vulnerability. This could allow unauthenticated access to the application or cause denial of service condition for existing users. The issue is based on rich client modules using IbsGailWrapper-interface. After issuing the record the authentication bypass vulnerability could take …
SIEMENS CERT
07/12/2022
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a DHCP client vulnerability (CVE-2021-29998) in the integrated SCALANCE X206-1 device. The vulnerability could allow an attacker to cause a heap-based buffer overflow on that device and use it to get access to the drive’s internal network. The list …
SIEMENS CERT
07/12/2022
EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30938). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
07/12/2022
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the console. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are …