Bulletins

SIEMENS CERT
09/28/2021
Siemens has released a new version for Solid Edge that fixes multiple file parsing vulnerabilities which could be triggered when the application reads files in IFC, JT or OBJ formats. If a user is tricked to opening a malicious file using the affected application this could lead the application to …
SIEMENS CERT
09/14/2021
SIMATIC S7-1200 PLC, version V4.5.0 fails to authenticate against configured passwords when the affected device was provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. Siemens has released an update for SIMATIC …
SIEMENS CERT
09/14/2021
The latest updates for the below mentioned products fix a vulnerability that allows an unauthenticated attacker to read PLC variables from affected devices without proper authentication under certain circumstances. Siemens has released updates for some of the affected products, is working on updates for the remaining affected products and recommends …
SIEMENS CERT
09/14/2021
Siemens Simcenter STAR-CCM+ Viewer is affected by a vulnerability that could be triggered when the application reads scene (.sce) files. If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction …
SIEMENS CERT
09/14/2021
Multiple vulnerabilities in RUGGEDCOM ROX devices have been detected, ranging from command injection to filesystem traversal. An attacker could exploit these to gain root access to the affected devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
09/14/2021
Siemens NX is affected by two vulnerabilities that could be triggered when the application reads ifc files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system. …
SIEMENS CERT
09/14/2021
A heap overflow vulnerability in dhclient of the affected products, which has been published alongside other vulnerabilities as part of NAME:WRECK could allow an attacker to potentially remotely execute code. Siemens recommends specific countermeasures for products.
SIEMENS CERT
09/14/2021
A vulnerability has been identified in the underlying TCP/IP stack of LOGO! CMR family and SIMATIC RTU 3000 family devices. It could allow an attacker with network access to the LAN interface of an affected device to hijack an ongoing connection or spoof a new one. The WAN interface, however, …