SIEMENS CERT
01/14/2020
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
01/14/2020
SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …
SIEMENS CERT
01/14/2020
Microsoft has released updates for several versions of Microsoft Windows, which fix a vulnerability in the Remote Desktop Service. The vulnerability could allow an unauthenticated remote attacker to execute arbitrary code on the target system if the system exposes the service to the network. RAPIDPoint® 500 systems operating on Windows …
SIEMENS CERT
01/14/2020
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
SIEMENS CERT
01/14/2020
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The underlying Wind River VxWorks network stack is affected by eleven vulnerabilities known as 'URGENT/11'. Of these, …
SIEMENS CERT
01/14/2020
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for some of the affected devices and is working on updates …
SIEMENS CERT
01/14/2020
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
01/14/2020
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens has released SIMATIC WinAC RTX (F) 2010 incl. SP3 Update 1 …