SIEMENS CERT
11/11/2025
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for the affected products and recommends to update to the …
SIEMENS CERT
11/11/2025
The web server of SICAM P850 and SICAM P855 devices, versions before V3.11, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. Siemens …
SIEMENS CERT
11/11/2025
SICAM GridEdge contains an improper access control vulnerability. This could allow persons with local access to the host system to inject an SSH key. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
Siemens Software Center and Solid Edge is affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/11/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
11/11/2025
LOGO! 8 BM (incl. SIPLUS variants) contains multiple vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state, or change the behavior of the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or …
CISA (ICS)
10/23/2025
1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : AutomationDirect Equipment : Productivity Suite Vulnerabilities : Relative Path Traversal, Weak Password Recovery Mechanism for Forgotten Password, Incorrect Permission Assignment for Critical Resource, Binding to an Unrestricted IP Address 2. RISK EVALUATION Successful exploitation of these …
CISA (ICS)
10/23/2025
1. EXECUTIVE SUMMARY CVSS v4 9.9 ATTENTION : Exploitable remotely/low attack complexity Vendor : ASKI Energy Equipment : ALS-Mini-S8, ALS-mini-s4 IP Vulnerability : Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain full control over the device. 3. TECHNICAL DETAILS …