Bulletins

SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
08/12/2025
SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller (BMC) that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. Siemens has released a new version for …
SIEMENS CERT
08/12/2025
A vulnerability in TIA Project Server and TIA Portal could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes …
SIEMENS CERT
08/12/2025
SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
08/12/2025
SIMATIC RTLS Locating Manager Before V3.2 contains an improper input validation vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
The basic authentication mechanism of Mendix Runtime contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
08/12/2025
SINEC OS before V3.1 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/12/2025
SICAM Q100 and Q200 devices are affected by two information disclosure vulnerabilities that could allow an authenticated local attacker to extract the SMTP account password and use the configured SMTP service for arbitrary purposes. Siemens has released new versions for the affected products and recommends to update to the latest …