CISA (ICS)
03/10/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor Equipment Vulnerabilities v3 9.8 Lantronix Lantronix EDS3000PS …
CISA (ICS)
03/10/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During …
SIEMENS CERT
03/10/2026
Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
03/10/2026
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
03/10/2026
COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
03/10/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
03/10/2026
Versions V5.0 through V8 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could allow privilege …
SIEMENS CERT
03/10/2026
SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …