Bulletins

SIEMENS CERT
10/14/2025
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures …
SIEMENS CERT
10/14/2025
The web server on SIMATIC S7-1200 CPU V2/V3 Before V3.0.2 contains a cross-site scripting (XSS) vulnerability that could allow remote attackers to inject arbitrary web script or HTML via a crafted URI. Siemens has released a new version for SIMATIC S7-1200 CPU V3 family (incl. SIPLUS variants) and recommends to …
SIEMENS CERT
10/14/2025
SIMATIC ET 200SP communication processors (CP 1542SP-1, CP 1542SP-1 IRC and CP 1543SP-1, incl. SIPLUS variants) contain an authentication vulnerability that could allow an unauthenticated remote attacker to access the configuration data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/14/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
10/14/2025
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the …
SIEMENS CERT
10/14/2025
TeleControl Server Basic V3.1 contains an information disclosure vulnerability that could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service. Siemens has released a new version for TeleControl Server Basic V3.1 and recommends to update to …
SIEMENS CERT
10/14/2025
SiPass integrated ACC (Advanced Central Controller) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
10/14/2025
Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted PRT files format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the …