SIEMENS CERT
06/10/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
06/10/2025
A vulnerability in SIRIUS 3RV2921-5M could allow an attacker to cause a denial of service condition. Siemens has released a new version for SIRIUS 3RV2921-5M and recommends to update to the latest version.
SIEMENS CERT
06/10/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update …
SIEMENS CERT
06/10/2025
The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. Siemens has released new versions for …
BOSCH PSIRT
06/10/2025
BOSCH-SA-992447-BT: A security vulnerability has been uncovered in the REST API of the Telex Remote Dispatch Console Server and the RTS VLink Virtual Matrix Software. The vulnerability will allow a Remote Code Execution (RCE) attack. All versions < 1.3.0 of the Telex Remote Dispatch Console Server are affected by this …
SIEMENS CERT
06/10/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
05/23/2025
SiPass integrated ACC (Advanced Central Controller) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
05/23/2025
SiPass integrated versions before V2.95.3.18 contain an out of bounds read vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition. Siemens has released a new version for SiPass integrated and recommends to update to the latest version.