May 2019
Title
Omron Network Configurator for DeviceNet
Published
May 14, 2019, 4:40 p.m.
Summary
This advisory includes mitigations for an untrusted search path vulnerability reported in Omron's Network Configurator for DeviceNet application.
Title
Siemens SIMATIC WinCC and SIMATIC PCS 7
Published
May 14, 2019, 4:35 p.m.
Summary
This advisory includes mitigations for a missing authentication for critical function vulnerability reported in Siemens' SIMATIC WinCC and SIMATIC PC7 products.
Title
Siemens LOGO! Soft Comfort
Published
May 14, 2019, 4:30 p.m.
Summary
This advisory includes mitigations for a deserialization of untrusted data vulnerability reported in Siemens' LOGO! Soft Comfort engineering software.
Title
Siemens LOGO!8 BM
Published
May 14, 2019, 4:25 p.m.
Summary
This advisory includes mitigations for missing authentication for critical function, improper handling of extra values, and plaintext storage of a password vulnerabilities reported in Siemens' LOGO!8 BM programmable logic controller.
Title
Siemens SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II
Published
May 14, 2019, 4:20 p.m.
Summary
This advisory includes mitigations for an uncontrolled resource consumption vulnerability reported in Siemens' SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II products.
Title
Siemens SINAMICS PERFECT HARMONY GH180 Fieldbus Network
Published
May 14, 2019, 4:15 p.m.
Summary
This advisory includes mitigations for an improper input validation vulnerability reported in Siemens' SINAMICS PERFECT HARMONY GH180 Fieldbus Network medium voltage converters.
Title
Siemens SIMATIC PCS 7, WinCC, TIA Portal
Published
May 14, 2019, 4:05 p.m.
Summary
This advisory includes mitigations for SQL injection, uncaught exception, and exposed dangerous method vulnerabilities reported in Siemens' SIMATIC PCS 7, WinCC, and TIA Portal products.
Title
Siemens SIMATIC Panels and WinCC (TIA Portal)
Published
May 14, 2019, 4 p.m.
Summary
This advisory includes mitigations for hard-coded community string, inadequate encryption, and cross-site scripting vulnerabilities reported in Siemens' SIMATIC Panels and WinCC (TIA Portal) products.
Title
SSA-606525 (Last Update: 2019-05-14): Denial-of-Service Vulnerability in SINAMICS PERFECT HARMONY GH180 Ethernet Modbus Interface (G28)
Published
May 14, 2019, 2 a.m.
Summary
SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II control contains a denial-of-service vulnerability within the Ethernet Modbus interface (G28). An attacker with access to the Ethernet Modbus Interface could cause a Denial-of-Service condition exceeding the number of available connections.
Title
SSA-113131 (Last Update: 2019-05-14): Denial-of-Service Vulnerabilities in S7-400 CPUs
Published
May 14, 2019, 2 a.m.
Summary
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a Denial-of-Service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens provides updates ...
Title
SSA-697412 (Last Update: 2019-05-14): Multiple Vulnerabilities in SIMATIC WinCC, SIMATIC WinCC Runtime, SIMATIC PCS 7, SIMATIC TIA Portal
Published
May 14, 2019, 2 a.m.
Summary
The latest update for SIMATIC WinCC fixes multiple vulnerabilities. The most severe could allow an attacker to execute arbitrary commands on an affected system under certain conditions. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and ...
Title
SSA-902727 (Last Update: 2019-05-14): Multiple Vulnerabilities in Licensing Software for SISHIP Automation Solutions
Published
May 14, 2019, 2 a.m.
Summary
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect SISHIP Automation Solutions. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
Title
SSA-865156 (Last Update: 2019-05-14): Denial-of-Service Vulnerability in SINAMICS PERFECT HARMONY GH180 Fieldbus Network
Published
May 14, 2019, 2 a.m.
Summary
SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II control contains a denial-of-service vulnerability within the Parameter Read/Write over Fieldbus network functionality. An attacker with access to the field bus network could cause a Denial-of-Service condition by sending specially crafted packets. By default, Parameter Read/Write over Fieldbus network is ...
Title
SSA-705517 (Last Update: 2019-05-14): Remote Code Execution Vulnerability in SIMATIC WinCC and SIMATIC PCS 7
Published
May 14, 2019, 2 a.m.
Summary
A vulnerability was identified in SIMATIC WinCC and SIMATIC PCS 7, which could allow an unauthenticated attacker with access to the affected devices to execute arbitrary code. The vulnerability can be exploited if the affected systems do not have "Encrypted Communication" enabled. Siemens provides versions of SIMATIC WinCC and SIMATIC ...
Title
SSA-307392 (Last Update: 2019-05-14): Denial-of-Service in OPC UA in Industrial Products
Published
May 14, 2019, 2 a.m.
Summary
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and ...
Title
SSA-480230 (Last Update: 2019-05-14): Denial-of-Service in Webserver of Industrial Products
Published
May 14, 2019, 2 a.m.
Summary
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Title
SSA-804486 (Last Update: 2019-05-14): Multiple Vulnerabilities in SIMATIC Panels and SIMATIC WinCC (TIA Portal)
Published
May 14, 2019, 2 a.m.
Summary
The latest update for SIMATIC Panel Software and SIMATIC WinCC (TIA Portal) fixes two vulnerabilities. The most severe is a vulnerability which could allow an attacker with network access to the integrated device to read and write variables via SNMP. Siemens recommends to update to the newest version.
Title
SSA-542701 (Last Update: 2019-05-14): Vulnerabilities in SIEMENS LOGO!
Published
May 14, 2019, 2 a.m.
Summary
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp.
Title
SSA-102144 (Last Update: 2019-05-14): Code Execution Vulnerability in LOGO! Soft Comfort
Published
May 14, 2019, 2 a.m.
Summary
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project.
Title
SSA-549547 (Last Update: 2019-05-14): Multiple Vulnerabilites in SCALANCE W1750D
Published
May 14, 2019, 2 a.m.
Summary
The latest update for SCALANCE W1750D fixes multiple vulnerabilities. The most severe could allow an unauthenticated attacker with access to the web interface of an affected device to execute arbitrary system commands within the underlying operating system. Siemens has released updates for the affected devices.
Title
SSA-592007 (Last Update: 2019-05-14): Denial-of-Service Vulnerability in Industrial Products
Published
May 14, 2019, 2 a.m.
Summary
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released ...
Title
Orpak SiteOmat
Published
May 2, 2019, 6:10 p.m.
Summary
This advisory includes mitigations for use of hard-coded credentials, cross-site scripting, SQL injection, missing encryption of sensitive data, code injection, and stack-based buffer overflow vulnerabilities reported in Orpak’s SiteOmat, software for fuel station management.
Title
Sierra Wireless AirLink ALEOS
Published
May 2, 2019, 6 p.m.
Summary
This advisory includes mitigations for OS command injection, use of hard-coded credentials, unrestricted upload of file with dangerous type, cross-site scripting, cross-site request forgery, information exposure, and missing encryption of sensitive data vulnerabilities reported in the Sierra Wireless AirLink ALEOS products.
April 2019
Title
Philips Tasy EMR
Published
April 30, 2019, 6:05 p.m.
Summary
This medical advisory includes mitigations for a cross-site scripting vulnerability reported in Philips’ Tasy EMR, a clinical and administrative workflow-based information system.
Title
Rockwell Automation CompactLogix 5370
Published
April 30, 2019, 6 p.m.
Summary
This advisory includes mitigations for uncontrolled resource consumption and stack-based buffer overflow vulnerabilities reported in Rockwell Automation’s CompactLogix 5370 controllers.

Last Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
26.11.2024
US CERT
08.11.2024
US CERT (ICS)
05.12.2024

By Source

Archive

2024
2023
2022
2021
2020
2019
2018
2017

Feeds