October 2019
Title
SSA-878278 (Last Update: 2019-10-08): Denial-of-Service Vulnerability in SIMATIC WinAC RTX (F) 2010
Published
Oct. 8, 2019, 2 a.m.
Summary
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens recommends specific countermeasures to mitigate this issue.
Title
SSA-275839 (Last Update: 2019-10-08): Denial-of-Service Vulnerability in Industrial Products
Published
Oct. 8, 2019, 2 a.m.
Summary
Several industrial products are affected by a vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. Siemens has released updates for several affected products, is working ...
Title
SSA-293562 (Last Update: 2019-10-08): Vulnerabilities in Industrial Products
Published
Oct. 8, 2019, 2 a.m.
Summary
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates ...
Title
SSA-473245 (Last Update: 2019-10-08): Denial-of-Service Vulnerability in Profinet Devices
Published
Oct. 8, 2019, 2 a.m.
Summary
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device.. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Title
SSA-121293 (Last Update: 2019-10-08): Code Upload Vulnerability in SIMATIC WinCC and SIMATIC PCS 7
Published
Oct. 8, 2019, 2 a.m.
Summary
The latest update for SIMATIC WinCC fixes a vulnerability in the SIMATIC WinCC DataMonitor web application of the affected products that allows to upload arbitrary ASPX code. An attacker has to be authenticated with a valid user account. The vulnerability is only relevant for scenarios where access via the web ...
Title
Interpeak IPnet TCP/IP Stack (Update A)
Published
Oct. 1, 2019, 4:15 p.m.
Summary
This updated medical advisory is a follow-up to the original advisory titled ICSMA-19-274-01 Interpeak IPnet TCP/IP Stack that was published October 1, 2019, on the ICS webpage on us-cert.gov. This updated medical advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the ...
Title
Interpeak IPnet TCP/IP Stack
Published
Oct. 1, 2019, 4:10 p.m.
Summary
This advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, integer underflow, improper restriction of operations within the bounds of a memory buffer, race condition, argument injection, and null pointer dereference vulnerabilities in the Interpeak IPnet TCP/IP stack.
Title
Yokogawa Products
Published
Oct. 1, 2019, 4:05 p.m.
Summary
This advisory includes mitigations for an unquoted search path or element vulnerability reported in Yokogawa’s Exaopc, Exaplog, Exaquantum, Exasmoc, Exarqe, GA10, and InsightSuiteAE products.
Title
Moxa EDR 810 Series
Published
Oct. 1, 2019, 4 p.m.
Summary
This advisory includes mitigations for improper input validation and improper access control vulnerabilities reported in Moxa’s EDR 810 router.
September 2019
Title
WECON LeviStudioU (Update A)
Published
Sept. 19, 2019, 3:55 p.m.
Summary
This updated advisory is a follow-up to the original advisory titled ICSA-19-036-03 WECON LeviStudioU that was published February 5, 2019, on the ICS webpage on us-cert.gov. This advisory includes mitigations for stack-based buffer overflow, heap-based buffer overflow, and memory corruption vulnerabilities reported in WECON's LeviStudioU.
Title
Siemens SINEMA Remote Connect Server
Published
Sept. 17, 2019, 4:05 p.m.
Summary
This advisory includes mitigations for improper restriction of excessive authentication attempts, information exposure, cross-site request forgery, and use of password hash with insufficient computational effort vulnerabilities in Siemens' SINEMA Remote Connect Server.
Title
Honeywell Performance IP Cameras and Performance NVRs
Published
Sept. 17, 2019, 4 p.m.
Summary
This advisory includes mitigations for an information exposure vulnerability in the Honeywell Performance IP Cameras and Performance NVRs product.
Title
Philips IntelliVue WLAN
Published
Sept. 12, 2019, 4:25 p.m.
Summary
This medical advisory contains mitigations for use of hard-coded password, and download of code without integrity check vulnerabilities in Philips IntelliVue WLAN firmware.
Title
3S-Smart Software Solutions GmbH CODESYS V3 Web Server
Published
Sept. 12, 2019, 4:20 p.m.
Summary
This advisory contains mitigations for path traversal and stack-based buffer overflow vulnerabilities in 3S-Smart Software Solutions' CODESYS V3 runtime systems.
Title
3S-Smart Software Solutions GmbH CODESYS V3 Library Manager
Published
Sept. 12, 2019, 4:15 p.m.
Summary
This advisory contains mitigations for a cross-site scripting vulnerability in 3S-Smart Software Solutions' CODESYS V3 library manager software.
Title
3S-Smart Software Solutions GmbH CODESYS Control V3 Online User Management
Published
Sept. 12, 2019, 4:10 p.m.
Summary
This advisory contains mitigations for an incorrect permission assignment for critical resource vulnerability in 3S-Smart Software Solutions' CODESYS Control V3 online user management software.
Title
3S-Smart Software Solutions GmbH CODESYS Control V3 OPC UA Server
Published
Sept. 12, 2019, 4:05 p.m.
Summary
This advisory contains mitigations for a NULL pointer dereference vulnerability in 3S-Smart Software Solutions' CODESYS Control V3 OPC UA Server.
Title
3S-Smart Software Solutions GmbH CODESYS V3 Products Containing a CODESYS Communication Server
Published
Sept. 12, 2019, 4 p.m.
Summary
This advisory contains mitigations for an improper input validation vulnerability in 3S-Smart Software Solutions' CODESYS V3 runtime systems.
Title
Improper Access Control in Access Professional Edition 3.7 downwards (CVE-2019-11899)
Published
Sept. 11, 2019, 2 a.m.
Summary

BOSCH-SA-844044-BT: A recently discovered security vulnerability affects Access Professional Edition (APE) installations of versions 3.7 and downwards. The vulnerability enables unauthorized access to sensitive data of the APE system. In cases where a software update is not possible, a reduction in the system’s network exposure is advised. Internet-accessible installations should ...

Title
Hard-coded Credentials in Access Professional Edition 3.7 downwards (CVE-2019-11898)
Published
Sept. 11, 2019, 2 a.m.
Summary

BOSCH-SA-710832-BT: A recently discovered security vulnerability affects Access Professional Edition (APE) installations of versions 3.7 and downwards. The vulnerability enables unauthorized access to sensitive data of the APE system. In cases where a software update is not possible, a reduction in the system’s network exposure is advised. Internet-accessible installations should ...

Title
Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU (Update A)
Published
Sept. 10, 2019, 4:30 p.m.
Summary
This updated alert is a follow-up to the original alert titled ICS-ALERT-19-225-01 Mitsubishi Electric smartRTU and INEA ME-RTU that was published August 13, 2019, on the ICS webpage on us-cert.gov. CISA is aware of a public report of a proof-of-concept (PoC) exploit code vulnerability affecting Mitsubishi Electric smartRTU devices. According ...
Title
Delta Electronics TPEditor
Published
Sept. 10, 2019, 4:25 p.m.
Summary
This advisory contains mitigations for stack-based buffer overflow, heap-based buffer overflow, and out-of-bounds write vulnerabilities in Delta Electronics' TPEditor, a programming software for Delta text panels.
Title
Siemens SINETPLAN
Published
Sept. 10, 2019, 4:20 p.m.
Summary
This advisory contains mitigations for an improper authorization vulnerability in Siemens' SINETPLAN automation systems planner.
Title
Siemens Industrial Products
Published
Sept. 10, 2019, 4:15 p.m.
Summary
This advisory contains mitigations for integer overflow or wraparound, and uncontrolled resource consumption vulnerabilities in Siemens' industrial products.
Title
Siemens IE-WSN-PA Link WirelessHART Gateway
Published
Sept. 10, 2019, 4:10 p.m.
Summary
This advisory contains mitigations for a cross-site scripting vulnerability in Siemens' IE/WSN-PA Link WirelessHART Gateway devices.

Last Updates

BOSCH PSIRT
15.01.2025
SIEMENS CERT
13.03.2025
US CERT
11.03.2025
US CERT (ICS)
13.03.2025

By Source

Archive

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds