SIEMENS CERT
06/14/2022
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released updates for several …
SIEMENS CERT
06/14/2022
Desigo PXC3, PXC4, PXC5 and DXR2 devices contain multiple vulnerabilities in the webserver application that could allow an attacker to potentially intercept unencrypted transmission of sensitive information, cause a denial of service condition, or perform remote code execution. Siemens has released updates for the affected products and recommends to update …
SIEMENS CERT
06/14/2022
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Update: The previously provided fixes only correctly set the permissions on English Windows versions. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, …
SIEMENS CERT
06/14/2022
Multiple vulnerabilities were identified in the webserver of the SICAM GridEdge application which includes missing authentication for critical API functions, absent cross-origin resource sharing restrictions and access to credentials. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/14/2022
On 2021-12-09, a vulnerability in Apache Log4j (a logging tool used in many Java-based applications) was disclosed, that could allow remote unauthenticated attackers to execute code on vulnerable systems. The vulnerability is tracked as CVE-2021-44228 and is also known as “Log4Shell”. On 2021-12-14 an additional denial of service vulnerability (CVE-2021-45046) …
SIEMENS CERT
06/14/2022
A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to disable and reset a device to factory state using a denial of service attack. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/14/2022
SIMATIC CP 1543-1 and CP 1545-1 devices are affected by multiple vulnerabilities in ProFTPD, a third party component, that could allow a remote attacker to access sensitive information and execute arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/14/2022
Multiple vulnerabilities were identified in the Apache HTTP Server software. These include NULL Pointer Dereferencing, Out-of-bounds Write and Server-Side Request Forgery related vulnerabilities. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version. Siemens is preparing further updates and recommends specific …