Bulletins

SIEMENS CERT
05/10/2022
SIMOTICS CONNECT 400, Desigo (Power PC-based), APOGEE MEC/MBC/PXC and TALON TC products are affected by a DHCP Client vulnerability as initially reported in SSA-434032 for the Mentor Nucleus Networking Module. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures …
SIEMENS CERT
05/10/2022
Multiple vulnerabilities (also known as “NUCLEUS:13”) have been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf. The products listed below use affected versions of the Nucleus software and inherently contain these vulnerabilities. Siemens has released updates for several affected products and …
SIEMENS CERT
05/10/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent . Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
05/10/2022
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released an update …
SIEMENS CERT
05/10/2022
Teamcenter is affected by XML External Entity Injection (XXE, CVE-2022-29801) and a stack based buffer overflow vulnerability (CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures …
SIEMENS CERT
05/10/2022
The open source software OpenV2G contains a buffer overflow vulnerability that could allow an attacker to trigger a memory corruption. Siemens has released an update for the OpenV2G and recommends to update to the latest version.
SIEMENS CERT
05/10/2022
Vulnerabilities in third-party component cURL could allow an attacker to interfere with the affected products in various ways. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends countermeasures for products where updates are not, or not …