05/13/2025
INTRALOG WMS before V5 is affected by multiple vulnerabilities in the Microsoft .NET implementation as described below. Siemens has released a new version for INTRALOG WMS and recommends to update to the latest version. Please approach your INTRALOG WMS contact to resolve the reported vulnerabilities for your solution. When contacting …
SIEMENS CERT
05/13/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
05/13/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
05/13/2025
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released a new version for Mendix OIDC SSO and recommends to update to the latest …
SIEMENS CERT
05/13/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
05/13/2025
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released new versions for several affected products and recommends to …
SIEMENS CERT
05/13/2025
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
05/13/2025
Polarion before V2410 contains multiple vulnerabilities that could allow attackers to extract data, conduct cross-site scripting attacks or find out valid usernames. Siemens strongly recommends to update Polarion to V2410 or later versions, not only to fix the documented vulnerabilities, but also to benefit from all the other improvements and …