Bulletins

SIEMENS CERT
10/08/2024
Multiple vulnerabilities (also known as “NUCLEUS:13”) have be identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/html/ssa-044112.html. Capital Embedded AR Classic uses an affected version of the Nucleus software and inherently contains several of these vulnerabilities. Siemens has released a new version …
SIEMENS CERT
10/08/2024
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for …
SIEMENS CERT
10/08/2024
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
10/08/2024
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/08/2024
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/08/2024
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 24.2.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/08/2024
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released new versions for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
10/08/2024
A vulnerability in Sentron Powercenter 1000 with 3RV2921-5M accessory could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.