Bulletins

SIEMENS CERT
08/13/2024
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not …
SIEMENS CERT
08/13/2024
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of …
SIEMENS CERT
08/13/2024
INTRALOG WMS before V4 is affected by vulnerabilities in the SQL Client-Server communication and in the .NET framework. Successful exploitation could allow an unauthenticated attacker located in the INTRALOG WMS network to decrypt and modify client-server communication, or potentially execute arbitrary code on the application servers. Siemens has released a …
SIEMENS CERT
08/13/2024
Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON powermanager, are affected by multiple vulnerabilities in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of these vulnerabilities could allow remote …
SIEMENS CERT
08/13/2024
TIA Project-Server formerly known as TIA Multiuser Server contains an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path. Siemens has released updates for several affected products and recommends to update to the …
SIEMENS CERT
08/13/2024
Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update (“2022.3 IPU – BIOS Advisory” Intel-SA-00688). Siemens is preparing updates and recommends specific countermeasures for products …
SIEMENS CERT
08/13/2024
COMOS before V10.5 is affected by two local code execution vulnerabilities in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.
SIEMENS CERT
08/13/2024
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.