CISA (ICS)
06/23/2026
Summary Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device. The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected: Aclara Metrum Cellular Web Interface CVSS Vendor Equipment Vulnerabilities v3 7.5 …
CISA (ICS)
06/23/2026
Summary SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to …
CISA (ALL)
06/23/2026
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation.
- CVE-2025-67038 Lantronix EDS5000 Code Injection Vulnerability
- CVE-2026-34908 Ubiquiti UniFi OS Improper Access Control Vulnerability
- CVE-2026-34909 Ubiquiti UniFi OS Path Traversal Vulnerability
- CVE-2026-34910 Ubiquiti UniFi OS …
CISA (ICS)
06/23/2026
Summary WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not …
CISA (ICS)
06/18/2026
Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, …
CISA (ICS)
06/18/2026
Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel …
CISA (ICS)
06/18/2026
Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided below may risk improper input validation which could …
CISA (ICS)
06/18/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian …