SIEMENS CERT
        03/12/2019
      
          Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
        
      
    SIEMENS CERT
        03/12/2019
      
          The latest updates for SINUMERIK controllers fix multiple security vulnerabilities that could allow an attacker to cause Denial-of-Service conditions, escalate privileges, or to execute code from remote. Siemens has released updates for several affected products, is working on updates for the remaining affected products and recommends specific countermeasures until fixes …
        
      
    SIEMENS CERT
        03/12/2019
      
          SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, and recommends specific countermeasures for the remaining products.
        
      
    SIEMENS CERT
        03/12/2019
      
          Security researchers published information on vulnerabilities known as Foreshadow and L1 Terminal Fault (L1TF). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
        
      
    SIEMENS CERT
        03/12/2019
      
          Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
        
      
    SIEMENS CERT
        03/12/2019
      
          A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
        
      
    SIEMENS CERT
        03/12/2019
      
          A vulnerability was identified in SIMATIC S7-1200 and S7-1500 CPUs that could allow an attacker to cause a denial-of-service condition preventing HMI or engineering access to the PLC over port 102/tcp. Siemens has released an update for the S7-1500 product and recommends that customers update to the new version. Siemens …
        
      
    SIEMENS CERT
        02/25/2019
      
          Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect WinCC OA. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.