SIEMENS CERT
05/13/2025
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and …
SIEMENS CERT
05/13/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
05/13/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens is preparing fix versions and recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
05/13/2025
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released a new version for Mendix OIDC SSO and recommends to update to the latest …
SIEMENS CERT
05/13/2025
APOGEE PXC and TALON TC Series (BACnet) Devices devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the …
SIEMENS CERT
05/13/2025
Desigo CC deployments that use Installed Client are impacted by an information disclosure vulnerability which could result in information leak from the Desigo CC server. The other Desigo CC client options, Windows App Client and Flex Client, are not affected by this vulnerability. Siemens recommends specific countermeasures for products where …
SIEMENS CERT
05/13/2025
Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user’s session even after logout. Siemens has released new versions for the affected products and recommends to update to …
SIEMENS CERT
05/13/2025
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the …