Bulletins

CISA (ICS)
03/10/2026
Summary Successful exploitation of this vulnerability could allow an unauthorized attacker to access controller management settings, control components, disclose information, or cause a denial-of-service condition. The following versions of Honeywell IQ4x BMS Controller are affected: IQ4E >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ412 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) IQ422 >=Firmware_v3.50_3.44|<4.36_build_4.3.7.9 (CVE-2026-3611) …
CISA (ICS)
03/10/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor Equipment Vulnerabilities v3 9.8 Lantronix Lantronix EDS3000PS …
CISA (ICS)
03/10/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During …
SIEMENS CERT
03/10/2026
Heliox EV Chargers listed below contain improper access control vulnerability that could allow an attacker to reach unauthorized services via the charging cable. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
03/10/2026
Siemens SINAMICS G220, SINAMICS S210, and SINAMICS S200 contains a privilege escalation vulnerability that could allow users to escalate their privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
03/10/2026
SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
03/10/2026
SINEC Security Monitor before V4.9.0 contains multiple vulnerabilities. Siemens has released a new version for SINEC Security Monitor and recommends to update to the latest version.
SIEMENS CERT
03/10/2026
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …