April 2023
Titel
SSA-592007 V2.0 (Last Update: 2023-04-11): Denial of Service Vulnerability in Industrial Products
Veröffentlicht
11. April 2023 02:00
Text
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens ...
Titel
SSA-691715 V1.0: Vulnerability in OPC Foundation Local Discovery Server Affecting Siemens Products
Veröffentlicht
11. April 2023 02:00
Text
A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released an update for SIMATIC WinCC and recommends to update to the latest version. Siemens is preparing further updates and recommends specific ...
Titel
SSA-676336 V1.2 (Last Update: 2023-04-11): OpenSSH Vulnerabilities in SCALANCE X-200 and X-300/X408 Switches
Veröffentlicht
11. April 2023 02:00
Text
The latest update of the SCALANCE X-200 and X-300/X408 switches families fixes multiple OpenSSH vulnerabilities. The most severe of these vulnerabilities could allow a denial of service condition. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and ...
Titel
SSA-780073 V2.3 (Last Update: 2023-04-11): Denial of Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
11. April 2023 02:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-712929 V1.9 (Last Update: 2023-04-11): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
11. April 2023 02:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-710008 V1.3 (Last Update: 2023-04-11): Multiple Web Vulnerabilities in SCALANCE Products
Veröffentlicht
11. April 2023 02:00
Text
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update ...
Titel
SSA-787941 V1.2 (Last Update: 2023-04-11): Denial of Service Vulnerability in RUGGEDCOM ROS V4
Veröffentlicht
11. April 2023 02:00
Text
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. ...
Titel
SSA-838121 V1.3 (Last Update: 2023-04-11): Multiple Denial of Service Vulnerabilities in Industrial Products
Veröffentlicht
11. April 2023 02:00
Text
Affected SIMATIC firmware contains three vulnerabilities that could allow an unauthenticated attacker to perform a denial of service attack under certain conditions. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet ...
Titel
SSA-813746 V1.0: BadAlloc Vulnerabilities in SCALANCE X-200, X-200IRT, and X-300 Switch Families
Veröffentlicht
11. April 2023 02:00
Text
Siemens has released a new firmware version for SCALANCE X-200 and X-200 IRT switches that address Bad Alloc vulnerabilities in the underlying operating system and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.
Titel
SSA-792594 V1.1 (Last Update: 2023-04-11): Host Header Injection Vulnerability in Polarion ALM
Veröffentlicht
11. April 2023 02:00
Text
Polarion ALM contains a misconfiguration in its default Apache HTTP Server configuration that could allow an attacker to perform host header injection attacks. Siemens has released an update for Polarion ALM and recommends to update to the latest version.
Titel
SSA-700053 V1.2 (Last Update: 2023-04-11): Multiple File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go
Veröffentlicht
11. April 2023 02:00
Text
Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads a malicious file in CGM or RAS format. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or ...
Titel
SSA-558014 V1.0: Third-Party Component Vulnerabilities in SCALANCE XCM332 before V2.2
Veröffentlicht
11. April 2023 02:00
Text
Multiple vulnerabilities in the third-party components cURL, BusyBox, libtirpc, Expat as well as in the Linux Kernel could allow an attacker to impact the SCALANCE XCM332 device’s confidentiality, integrity and availability. Siemens has released an update for the SCALANCE XCM332 and recommends to update to the latest version.
Titel
SSA-840800 V1.3 (Last Update: 2023-04-11): Code Injection Vulnerability in RUGGEDCOM ROS
Veröffentlicht
11. April 2023 02:00
Text
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products ...
Titel
SSA-840188 V1.6 (Last Update: 2023-04-11): Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Veröffentlicht
11. April 2023 02:00
Text
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are ...
Titel
SSA-699404 V1.0: Observable Response Discrepancy in Mendix Forgot Password Module
Veröffentlicht
11. April 2023 02:00
Text
The Mendix Forgot Password module contains an observable response discrepancy issue that could allow an attacker to retrieve sensitive information. Siemens has released updates for the affected products and recommends to update to the latest versions.
März 2023
Titel
SSA-250085 V1.2 (Last Update: 2023-03-14): Multiple Vulnerabilities in SINEC NMS and SINEMA Server
Veröffentlicht
14. März 2023 01:00
Text
SINEC NMS and SINEMA Server V14 contains multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. Siemens has released an update for SINEC NMS to fix CVE-2022-24281 and recommends to update to the latest version. ...
Titel
SSA-244969 V1.9 (Last Update: 2023-03-14): OpenSSL Vulnerability in Industrial Products
Veröffentlicht
14. März 2023 01:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to ...
Titel
SSA-223771 V1.2 (Last Update: 2023-03-14): SISCO Stack Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
14. März 2023 01:00
Text
A vulnerability in the third party component SISCO MMS-EASE could allow attackers to cause a denial of service condition with SIPROTEC 5 devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products ...
Titel
SSA-256353 V1.3 (Last Update: 2023-03-14): Third-Party Component Vulnerabilities in RUGGEDCOM ROS
Veröffentlicht
14. März 2023 01:00
Text
Multiple vulnerabilities affect various third-party components of the RUGGEDCOM Operating System (ROS). If exploited, an attacker could cause a denial-of-service, act as a man-in-the-middle or retrieval of sensitive information or gain privileged functions. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-260625 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.2
Veröffentlicht
14. März 2023 01:00
Text
RUGGEDCOM CROSSBOW V5.2 fixes two vulnerabilities that could allow authenticated remote attackers to perform unauthorized actions (CVE-2023-27309) or escalate privileges (CVE-2023-27310). Siemens has released an update for RUGGEDCOM CROSSBOW and recommends to update to the latest version.
Titel
SSA-320629 V1.0: Security Vulnerabilities Fixed in RUGGEDCOM CROSSBOW V5.3
Veröffentlicht
14. März 2023 01:00
Text
RUGGEDCOM CROSSBOW before V5.3 contains two vulnerabilities that could allow authenticated remote attackers to access data they are not authorized for, or execute arbitrary database queries via an SQL injection attack. Siemens has released an update for RUGGEDCOM CROSSBOW and recommends to update to the latest version.
Titel
SSA-203374 V1.0: Multiple OpenSSL Vulnerabilities in SCALANCE W1750D Devices
Veröffentlicht
14. März 2023 01:00
Text
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSB-439005 V5.1 (Last Update: 2023-03-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
14. März 2023 01:00
Text
Titel
SSA-419740 V1.0: Multiple Third-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2
Veröffentlicht
14. März 2023 01:00
Text
Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special elements to improper handling of commands under certain circumstances, that could lead to code injection and ...
Titel
SSA-413565 V1.1 (Last Update: 2023-03-14): Multiple Vulnerabilities in SCALANCE Products
Veröffentlicht
14. März 2023 01:00
Text
Multiple SCALANCE devices are affected by several vulnerabilities that could allow an attacker to inject code, retrieve data as debug information as well as user CLI passwords or set the CLI to an irresponsive state. Siemens has released updates for several affected products and recommends to update to the latest ...

Letzte Updates

BOSCH PSIRT
10.06.2025
SIEMENS CERT
21.07.2025
US CERT
29.07.2025
US CERT (ICS)
31.07.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds