Bulletins

SIEMENS CERT
08/12/2025
Simcenter Femap contains a file parsing vulnerability that could be triggered when the application reads files in STP or BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
08/12/2025
A denial of service vulnerability could allow an unauthorized attacker to cause total loss of availability in the web server of the affected devices. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
08/12/2025
An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/12/2025
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens has released new versions for the affected …
SIEMENS CERT
08/12/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
08/12/2025
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …
SIEMENS CERT
08/12/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.