SIEMENS CERT
10/14/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
10/14/2025
SIMATIC S7-1200 CPU V1/V2 controllers contain two vulnerabilities that could allow an unauthenticated remote attacker to trigger functions by record and playback of legitimate network communication, or to place the controller in stop/defect state by causing a communications error. Siemens has released new versions for the affected products and recommends …
SIEMENS CERT
10/14/2025
SiPass integrated before V3.0 contains multiple vulnerabilities that could allow an unauthenticated remote attacker to exploit user accounts, manipulate data, impersonate users, or achieve arbitrary code execution on the SiPass integrated server. Siemens has released a new version for SiPass integrated and recommends to update to the latest version.
SIEMENS CERT
10/14/2025
Siemens’ User Management Component (UMC) is affected by multiple vulnerabilities that could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. Siemens has released a new version for User Management Component (UMC) and recommends to update to the latest version. Siemens is …
SIEMENS CERT
10/14/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
10/14/2025
Siemens User Management Component (UMC) is affected by three vulnerabilities which could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific …
SIEMENS CERT
10/14/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
10/14/2025
Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted PRT files format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the …