Januar 2025
Titel
SSA-446448 V2.3 (Last Update: 2025-01-14): Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Veröffentlicht
14. Januar 2025 01:00
Text
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific ...
Titel
SSA-999588 V1.7 (Last Update: 2025-01-14): Multiple Vulnerabilities in User Management Component (UMC) Before V2.11.2
Veröffentlicht
14. Januar 2025 01:00
Text
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Titel
SSA-876787 V1.3 (Last Update: 2025-01-14): Open Redirect Vulnerability in SIMATIC S7-1500 and S7-1200 CPUs
Veröffentlicht
14. Januar 2025 01:00
Text
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens ...
Titel
SSA-871035 V1.1 (Last Update: 2025-01-14): Session-Memory Deserialization Vulnerability in Siemens Engineering Platforms Before V19
Veröffentlicht
14. Januar 2025 01:00
Text
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for ...
Titel
SSA-773256 V1.3 (Last Update: 2025-01-14): Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products
Veröffentlicht
14. Januar 2025 01:00
Text
A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products. Siemens has released new versions for several affected ...
Titel
SSA-723487 V1.4 (Last Update: 2025-01-14): RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products
Veröffentlicht
14. Januar 2025 01:00
Text
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to ...
Titel
SSA-730482 V1.2 (Last Update: 2025-01-14): Denial of Service Vulnerability in SIMATIC WinCC
Veröffentlicht
14. Januar 2025 01:00
Text
A vulnerability in the login dialog box of SIMATIC WinCC could allow a local attacker to cause a denial of service condition in the runtime of the SCADA system. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Dezember 2024
Titel
SSA-928984 V1.0: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Veröffentlicht
16. Dezember 2024 01:00
Text
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for ...
Titel
SSA-979056 V1.1 (Last Update: 2024-12-12): Out of Bounds Write Vulnerability in Parasolid
Veröffentlicht
12. Dezember 2024 01:00
Text
Parasolid is affected by an out of bounds write vulnerability that could be triggered when the application is parsing X_T data or a specially crafted file in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to ...
Titel
SSA-097435 V1.7 (Last Update: 2024-12-12): Usernames Disclosure Vulnerability in Mendix Runtime
Veröffentlicht
12. Dezember 2024 01:00
Text
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note that some, Mendix Runtime version lines ...
Titel
SSA-042050 V1.2 (Last Update: 2024-12-10): Know-How Protection Mechanism Failure in TIA Portal
Veröffentlicht
10. Dezember 2024 01:00
Text
The know-how protection feature in Totally Integrated Automation Portal (TIA Portal) does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the ...
Titel
SSA-097435 V1.6 (Last Update: 2024-12-10): Usernames Disclosure Vulnerability in Mendix Runtime
Veröffentlicht
10. Dezember 2024 01:00
Text
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note that some, Mendix Runtime version lines ...
Titel
SSA-364175 V1.4 (Last Update: 2024-12-10): Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 Devices Before V11.1.4-h1
Veröffentlicht
10. Dezember 2024 01:00
Text
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds ...
Titel
SSA-264814 V1.4 (Last Update: 2024-12-10): Timing Based Side Channel Vulnerability in the OpenSSL RSA Decryption in SIMATIC Products
Veröffentlicht
10. Dezember 2024 01:00
Text
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are ...
Titel
SSA-340240 V1.1 (Last Update: 2024-12-10): Denial of Service Vulnerability in SENTRON Powercenter 1000/1100 With 3RV2921-5M Accessory
Veröffentlicht
10. Dezember 2024 01:00
Text
A vulnerability in SENTRON Powercenter 1000/1100 with 3RV2921-5M accessory could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-384652 V1.0: Cross-Site Request Forgery (CSRF) Vulnerability in RUGGEDCOM ROX II
Veröffentlicht
10. Dezember 2024 01:00
Text
The CLI feature in the web interface of RUGGEDCOM ROX II devices is vulnerable to cross-site request forgery (CSRF), which could allow an attacker to perform administrative actions if an authenticated user is tricked into accessing a malicious link. Siemens has released new versions for the affected products and recommends ...
Titel
SSA-128393 V1.0: Firmware Decryption Vulnerability in SICAM A8000 CP-8031 and CP-8050
Veröffentlicht
10. Dezember 2024 01:00
Text
The SICAM A8000 CP-8031 and CP-8050 devices are affected by a vulnerability that could allow an attacker with physical access to the device to decrypt the firmware. Siemens has released new firmware and hardware versions for the affected products and recommends to update to the latest versions. Both the firmware ...
Titel
SSA-264815 V1.3 (Last Update: 2024-12-10): Type Confusion Vulnerability in OpenSSL X.400 Address Processing in SIMATIC Products
Veröffentlicht
10. Dezember 2024 01:00
Text
Several SIMATIC products are affected by a type confusion vulnerability relating to OpenSSL X.400 address processing (CVE-2023-0286), as disclosed disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are ...
Titel
SSA-398330 V2.1 (Last Update: 2024-12-10): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Veröffentlicht
10. Dezember 2024 01:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Titel
SSA-392859 V1.0: Local Arbitrary Code Execution Vulnerability in Siemens Engineering Platforms before V20
Veröffentlicht
10. Dezember 2024 01:00
Text
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. Siemens has released products based on the Totally ...
Titel
SSA-620799 V1.0: Denial of Service Vulnerability During BLE Pairing in SENTRON Powercenter 1000/1100
Veröffentlicht
10. Dezember 2024 01:00
Text
SENTRON Powercenter devices are affected by a denial of service vulnerability that can be triggered during BLE (Bluetooth Low Energy) pairing. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-701627 V1.0: XXE Injection Vulnerabilities in COMOS
Veröffentlicht
10. Dezember 2024 01:00
Text
COMOS is affected by XXE injection vulnerabilities that could allow an attacker to extract arbitrary application files. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-711309 V2.2 (Last Update: 2024-12-10): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
10. Dezember 2024 01:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released new versions for several affected products and ...
Titel
SSA-698820 V1.4 (Last Update: 2024-12-10): Multiple Vulnerabilities in Fortigate NGFW Before V7.4.4 on RUGGEDCOM APE1808 Devices
Veröffentlicht
10. Dezember 2024 01:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-673996 V1.1 (Last Update: 2024-12-10): Buffer Overflow Vulnerability in Third-Party Component in SICAM and SITIPE Products
Veröffentlicht
10. Dezember 2024 01:00
Text
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 ...