SIEMENS CERT
11/11/2025
Spectrum Power 4 before v4.70 SP12 Security Patch 2 contains multiple vulnerabilities that could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator. Siemens has released a new version for Spectrum Power 4 and recommends to update to the latest version.
SIEMENS CERT
10/14/2025
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
10/14/2025
TeleControl Server Basic V3.1 contains an information disclosure vulnerability that could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service. Siemens has released a new version for TeleControl Server Basic V3.1 and recommends to update to …
SIEMENS CERT
10/14/2025
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
10/14/2025
Several SIMATIC S7-1500 CPU versions are affected by an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
10/14/2025
SIMATIC S7-1200 CPU V2 devices contain an insufficiently protected private key used for the Certificate Authority (CA) for HTTPS connections. Possession of this key could allow remote attackers to spoof the device’s web server by creating a forged web server certificate. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
10/14/2025
The web server on SIMATIC S7-1200 CPU V2/V3 Before V3.0.2 contains a cross-site scripting (XSS) vulnerability that could allow remote attackers to inject arbitrary web script or HTML via a crafted URI. Siemens has released a new version for SIMATIC S7-1200 CPU V3 family (incl. SIPLUS variants) and recommends to …
SIEMENS CERT
10/14/2025
SIMOTION SCOUT, SIMOTION SCOUT TIA and SINAMICS STARTER are affected by an XXE injection vulnerability that could allow an attacker to access arbitrary application files. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends …