SIEMENS CERT
08/12/2025
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
COMOS before V10.6 is affected by a local arbitrary code execution vulnerability in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
08/12/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., a SICAM device) and a RADIUS server, to forge Access-Request packets in …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …
SIEMENS CERT
08/12/2025
Affected SIPROTEC 5 devices contain a development shell which is accessible via a physical interface which is not properly restricted. This could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. Siemens has released new versions for several affected products and …