November 2021
Titel
SSA-145157 V1.0: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12
Veröffentlicht
9. November 2021 01:00
Text
SIMATIC RTLS Locating Manager before V2.12 contains multiple vulnerabilities that could allow an attacker to read sensitive data or trigger a denial-of-service condition of the application service. Siemens has released an update for the SIMATIC RTLS Locating Manager and recommends to update to the latest version.
Titel
SSA-772220 V1.3 (Last Update: 2021-11-09): OpenSSL Vulnerabilities in Industrial Products
Veröffentlicht
9. November 2021 01:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens has released updates for several affected products and recommends to update to the latest versions. ...
Titel
SSA-705111 V1.1 (Last Update: 2021-11-09): Multiple Vulnerabilities (NAME:WRECK) in the DNS Module of Nucleus RTOS
Veröffentlicht
9. November 2021 01:00
Text
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerabilities described in this advisory are from this set. The DNS client of affected products contains multiple vulnerabilities related to the handling of DNS responses and requests. The most severe could allow an ...
Titel
SSA-675303 V1.2 (Last Update: 2021-11-09): WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products
Veröffentlicht
9. November 2021 01:00
Text
WIBU Systems published information about two vulnerabilities and an associated fix release version of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2021-20093 and CVE-2021-20094. ...
Titel
SSB-439005 V3.9 (Last Update: 2021-11-09): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
9. November 2021 01:00
Text
Titel
SSA-362164 V1.1 (Last Update: 2021-11-09): Predictable Initial Sequence Numbers in the TCP/IP Stack of Nucleus RTOS
Veröffentlicht
9. November 2021 01:00
Text
The networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) use Initial Sequence Numbers for TCP-Sessions that are predictable. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not available.
Titel
SSA-312271 V1.9 (Last Update: 2021-11-09): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
9. November 2021 01:00
Text
Several industrial products as listed below contain a local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-248289 V1.1 (Last Update: 2021-11-09): Denial of Service Vulnerabilities in the IPv6 Stack of Nucleus RTOS
Veröffentlicht
9. November 2021 01:00
Text
The IPv6 stack of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two vulnerabilities when processing IPv6 headers which could allow an attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the latest versions. ...
Titel
SSA-201384 V1.1 (Last Update: 2021-11-09): Predictable UDP Port Number Vulnerability (NAME:WRECK) in the DNS Module of Nucleus RTOS
Veröffentlicht
9. November 2021 01:00
Text
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerability described in this advisory is from this set. The DNS client of of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains a vulnerability related to the handling of ...
Titel
SSA-185699 V1.1 (Last Update: 2021-11-09): Out of Bounds Write Vulnerabilities (NAME:WRECK) in the DNS Module of Nucleus RTOS
Veröffentlicht
9. November 2021 01:00
Text
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerabilities described in this advisory are from this set. The DNS client of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains two out of bounds write vulnerabilities in the ...
Titel
SSA-917476 V1.0: Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
9. November 2021 01:00
Text
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to execute code on the affected device(s), read arbitrary files, or create a denial-of-service condition. Siemens has released an update for the SCALANCE W1750D and recommends to update to the latest version. Siemens is preparing further updates and ...
Titel
SSA-840188 V1.0: Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Veröffentlicht
9. November 2021 01:00
Text
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products ...
Titel
SSA-779699 V1.0: Two Incorrect Authorization Vulnerabilities in Mendix
Veröffentlicht
9. November 2021 01:00
Text
Applications built with affected versions of Mendix Studio Pro do not properly control read or write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects or to retrieve the changedDate attribute of arbitrary objects. Mendix has released updates for the affected product ...
Titel
SSA-755517 V1.0: Path Traversal Vulnerability in Siveillance Video DLNA Server
Veröffentlicht
9. November 2021 01:00
Text
Siemens has released hotfixes for Siveillance Video DLNA Server, which fix a path traversal vulnerability that could allow an authenticated remote attacker to access sensitive information on the DLNA server. Siemens has released updates for the DLNA server and recommends to apply the update on all installations where DLNA server ...
Titel
SSA-740908 V1.0: File Parsing Vulnerabilities in JT Translator in NX
Veröffentlicht
9. November 2021 01:00
Text
Siemens NX is affected by two vulnerabilities that could be triggered when the application reads JT files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system. ...
Titel
SSA-703715 V1.0: Information Disclosure Vulnerability in Climatix POL909 (AWM)
Veröffentlicht
9. November 2021 01:00
Text
Climatix POL909 (AWM module) contains an information disclosure vulnerability could allow an attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit. Siemens has released an update for Climatix POL909 (AWM module) and recommends to update to the latest version.
Titel
SSA-537983 V1.0: Local Code Execution Vulnerability in SENTRON powermanager V3
Veröffentlicht
9. November 2021 01:00
Text
SENTRON powermanager V3 is affected by a vulnerability that could allow a local attacker to inject arbitrary code and escalate privileges. Siemens has released a security patch for SENTRON powermanager V3.6 HF1 and recommends to update to the latest version and apply this patch.
Titel
SSA-580693 V1.0: WIBU Systems CodeMeter Runtime Denial-of-Service Vulnerability in Siemens Products
Veröffentlicht
9. November 2021 01:00
Text
WIBU Systems published information about a denial-of-service vulnerability and an associated fix release version of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens products for license management. The vulnerability is described in the section “Vulnerability Classification” below and got assigned the CVE ID CVE-2021-41057. Successful ...
Oktober 2021
Titel
SSA-557804 V1.3 (Last Update: 2021-10-12): Mirror Port Isolation Vulnerability in SCALANCE X Switches
Veröffentlicht
12. Oktober 2021 02:00
Text
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures ...
Titel
SSA-913875 V1.1 (Last Update: 2021-10-12): Frame Aggregation and Fragmentation Vulnerabilities in 802.11
Veröffentlicht
12. Oktober 2021 02:00
Text
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The ...
Titel
SSA-847986 V1.1 (Last Update: 2021-10-12): Denial-of-Service Vulnerabilities in SIPROTEC 5 relays
Veröffentlicht
12. Oktober 2021 02:00
Text
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
Titel
SSA-780073 V1.9 (Last Update: 2021-10-12): Denial-of-Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
12. Oktober 2021 02:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versMions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing ...
Titel
SSA-723417 V1.2 (Last Update: 2021-10-12): Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
12. Oktober 2021 02:00
Text
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-599968 V1.3 (Last Update: 2021-10-12): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
12. Oktober 2021 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-541018 V1.3 (Last Update: 2021-10-12): Embedded TCP/IP Stack Vulnerabilities (AMNESIA:33) in SENTRON PAC / 3VA Devices (Part 2)
Veröffentlicht
12. Oktober 2021 02:00
Text
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of two of these vulnerabilities (CVE-2020-13987, CVE-2020-17437) to Siemens products. Siemens has released updates for several affected products and recommends to update to the latest ...

Letzte Updates

BOSCH PSIRT
25.04.2025
SIEMENS CERT
13.05.2025
US CERT
01.04.2025
US CERT (ICS)
13.05.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds