SIEMENS CERT
03/12/2024
Siveillance Control does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges. Siemens has released a new version for Siveillance Control and recommends to …
SIEMENS CERT
03/12/2024
Several products used in Sinteso EN and Cerberus PRO EN Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected products (CVE-2024-22039) …
SIEMENS CERT
03/12/2024
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
03/12/2024
SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
03/12/2024
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
SIEMENS CERT
03/12/2024
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not …
SIEMENS CERT
03/12/2024
Devices of the SIPROTEC 5 family contain a vulnerability related to secure client-initiated renegotiation. This could allow an unauthenticated attacker to cause a denial of service condition for the duration of the attack. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
03/12/2024
SINEMA Remote Connect Server before V3.2 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.