SIEMENS CERT
08/12/2025
SICAM Q100 and Q200 devices are affected by two information disclosure vulnerabilities that could allow an authenticated local attacker to extract the SMTP account password and use the configured SMTP service for arbitrary purposes. Siemens has released new versions for the affected products and recommends to update to the latest …
SIEMENS CERT
08/12/2025
SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
SSA-493787 V1.0: Arbitrary Code Execution Vulnerability in SIMATIC RTLS Locating Manager Before V3.2
SIMATIC RTLS Locating Manager Before V3.2 contains an improper input validation vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
07/21/2025
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The integrated ICMP services in the underlying TCP/IP stack is vulnerable to a denial of service attack through specially crafted ICMP packets. A successful attack will impact the availability …
SIEMENS CERT
07/18/2025
During establishment of a https connection to the TLS server of a managed device, SICAM TOOLBOX II improperly validates that device’s certificate. This could allow an attacker to execute an on-path network (MitM) attack. Siemens has released a new version for SICAM TOOLBOX II and recommends to update to the …
SIEMENS CERT
07/10/2025
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The integrated ICMP services in the underlying TCP/IP stack is vulnerable to a denial of service attack through specially crafted ICMP packets. A successful attack will impact the availability …
SIEMENS CERT
07/08/2025
A sensitive data exposure vulnerability in SIPROTEC 5 can allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
07/08/2025
During establishment of a https connection to the TLS server of a managed device, SICAM TOOLBOX II improperly validates that device’s certificate. This could allow an attacker to execute an on-path network (MitM) attack. Siemens has released a new version for SICAM TOOLBOX II and recommends to update to the …