SIEMENS CERT
11/11/2025
SICAM GridEdge contains an improper access control vulnerability. This could allow persons with local access to the host system to inject an SSH key. Siemens has released a new version for SICAM GridEdge (Classic) and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
Affected SIPROTEC 5 devices do not properly limit the access of the web server to the filesystem. This could allow an authenticated remote attacker to read arbitrary files or the entire filesystem of the device. Siemens has released new versions for the affected products and recommends to update to the …
SIEMENS CERT
11/11/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
11/11/2025
LOGO! 8 BM (incl. SIPLUS variants) contains multiple vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state, or change the behavior of the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
11/11/2025
The web interface of RUGGEDCOM ROX II devices contain multiple Client-Side Enforcement of Server-Side Security vulnerabilities that could allow an attacker with a legitimate, highly privileged account on the web interface to get privileged code execution in the underlying OS of the affected products. Siemens has released new versions for …
SIEMENS CERT
11/11/2025
Spectrum Power 4 before v4.70 SP12 Security Patch 2 contains multiple vulnerabilities that could allow an attacker to remotely execute code as application administrator or locally execute code as operating system administrator. Siemens has released a new version for Spectrum Power 4 and recommends to update to the latest version.
SIEMENS CERT
11/11/2025
SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released new versions for the affected products and recommends to update to the …
SIEMENS CERT
11/11/2025
Siemens Software Center and Solid Edge is affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. Siemens has released new versions for the affected products and recommends to update to the latest versions.