SIEMENS CERT
06/11/2024
TIA Administrator creates temporary download files in a directory with insecure permissions. This could allow any authenticated attacker on Windows to disrupt the update process. Siemens has released a new version for TIA Administrator and recommends to update to the latest version.
SIEMENS CERT
06/11/2024
Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
06/11/2024
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family is affected by multiple vulnerabilities. CVE-2023-44318 and CVE-2023-44321 were previously published as part of SSA-699386. Siemens recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
06/11/2024
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not …
SIEMENS CERT
06/11/2024
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of …
SIEMENS CERT
06/11/2024
Apps built with Mendix Runtime >= V9.3 could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights. Siemens has released new versions for …
SIEMENS CERT
06/11/2024
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
06/11/2024
SIMATIC S7-200 SMART devices contain an information disclosure vulnerability which leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. Siemens …