CISA (ICS)
06/23/2026
Summary SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version. The following versions of Siemens SINEC INS are affected: SINEC INS vers:intdot/<1.0.2.6 CVSS Vendor Equipment Vulnerabilities v3 8.8 …
CISA (ICS)
06/23/2026
Summary Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device. The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected: Aclara Metrum Cellular Web Interface CVSS Vendor Equipment Vulnerabilities v3 7.5 …
CISA (ICS)
06/18/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion'), …
CISA (ICS)
06/18/2026
Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External Parties Background …
CISA (ICS)
06/18/2026
Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided below may risk improper input validation which could …
CISA (ICS)
06/18/2026
Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, …
CISA (ICS)
06/18/2026
Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel …
CISA (ICS)
06/18/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian …