SIEMENS CERT
08/12/2025
SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
SICAM Q100 and Q200 devices are affected by two information disclosure vulnerabilities that could allow an authenticated local attacker to extract the SMTP account password and use the configured SMTP service for arbitrary purposes. Siemens has released new versions for the affected products and recommends to update to the latest …
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
08/12/2025
A vulnerability in TIA Project Server and TIA Portal could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes …
SIEMENS CERT
08/12/2025
SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
08/12/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update …
SIEMENS CERT
08/12/2025
SSA-493787 V1.0: Arbitrary Code Execution Vulnerability in SIMATIC RTLS Locating Manager Before V3.2
SIMATIC RTLS Locating Manager Before V3.2 contains an improper input validation vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
RUGGEDCOM ROX II devices does not properly enforce limitations on type and size of files that can be uploaded through their web interface. This could allow an attacker with a legitimate, highly privileged account on the web interface to upload arbitrary files onto the filesystem of the devices. Siemens is …