Juni 2020
Titel
SSA-312271 (Last Update: 2020-06-09): Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications
Veröffentlicht
9. Juni 2020 02:00
Text
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens ...
Titel
SSA-480230 (Last Update: 2020-06-09): Denial-of-Service in Webserver of Industrial Products
Veröffentlicht
9. Juni 2020 02:00
Text
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Titel
SSA-352504 (Last Update: 2020-06-09): Urgent/11 TCP/IP Stack Vulnerabilities in Siemens Power Meters
Veröffentlicht
9. Juni 2020 02:00
Text
Siemens low & high voltage power meters are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by eleven vulnerabilities known as the "URGENT/11". The vulnerability could allow an attacker to execute a variety of exploits for the purpose of Denial-of-Service ...
Titel
SSA-927095 (Last Update: 2020-06-09): UltraVNC Vulnerabilities in SINUMERIK Products
Veröffentlicht
9. Juni 2020 02:00
Text
UltraVNC (V1.2.2.3 and below) vulnerabilities in the affected products could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends that customers update to the latest versions.
Titel
SSA-689942 (Last Update: 2020-06-09): Denial-of-Service and DLL Hijacking Vulnerabilities in Multiple SIMATIC Software Products
Veröffentlicht
9. Juni 2020 02:00
Text
Multiple SIMATIC Software products are affected by two vulnerabilities that could allow an attacker to manipulate project files that may lead to Remote Code Execution or Denial-of-Service attacks. Siemens has released updates to some of the affected products and recommends that customers update to the latest version. Siemens is preparing ...
Mai 2020
Titel
SSA-377115 (Last Update: 2020-05-12): SegmentSmack in Linux IP-Stack based Industrial Devices
Veröffentlicht
12. Mai 2020 02:00
Text
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has ...
Titel
SSB-439005 (Last Update: 2020-05-12): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
12. Mai 2020 02:00
Text
Titel
SSA-352504 (Last Update: 2020-05-12): Urgent/11 TCP/IP Stack Vulnerabilities in Siemens Power Meters
Veröffentlicht
12. Mai 2020 02:00
Text
Siemens low & high voltage power meters are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by eleven vulnerabilities known as the "URGENT/11". The vulnerability could allow an attacker to execute a variety of exploits for the purpose of Denial-of-Service ...
Titel
SSA-530931 (Last Update: 2020-05-12): Denial-of-Service in Webserver of Industrial Products
Veröffentlicht
12. Mai 2020 02:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends ...
Titel
SSA-593272 (Last Update: 2020-05-12): SegmentSmack in Interniche IP-Stack based Industrial Devices
Veröffentlicht
12. Mai 2020 02:00
Text
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service.
Titel
SSA-899560 (Last Update: 2020-05-12): Vulnerabilities in SIPROTEC 5 relays and DIGSI 5
Veröffentlicht
12. Mai 2020 02:00
Text
The SIPROTEC 5 relays and their corresponding engineering software DIGSI 5 are affected by two security vulnerabilities which could allow an attacker to upload or download files to the device or to conduct a Denial-of-Service attack over the network. Siemens has released updates for some affected products, is working on ...
Titel
SSA-270778 (Last Update: 2020-05-12): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software
Veröffentlicht
12. Mai 2020 02:00
Text
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are ...
April 2020
Titel
SSA-886514 (Last Update: 2020-04-14): Persistent XSS Vulnerabilities in the Web Interface of Climatix POL908 and POL909 Modules
Veröffentlicht
14. April 2020 02:00
Text
The Climatix BACnet/IP (POL908) and AWM (POL909) modules contain two persistent cross-site scripting (XSS) vulnerabilities in the web interface that could allow a remote attacker to execute arbitrary JavaScript code in the context of other users' web sessions. Siemens recommends to update Climatix POL908 and POL909 to the latest version ...
Titel
SSA-102233 (Last Update: 2020-04-14): SegmentSmack in VxWorks-based Industrial Devices
Veröffentlicht
14. April 2020 02:00
Text
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is ...
Titel
SSA-462066 (Last Update: 2020-04-14): Vulnerability known as TCP SACK PANIC in Industrial Products
Veröffentlicht
14. April 2020 02:00
Text
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products, and recommends that customers update to the latest version. Siemens is preparing ...
Titel
SSA-593272 (Last Update: 2020-04-14): SegmentSmack in Interniche IP-Stack based Industrial Devices
Veröffentlicht
14. April 2020 02:00
Text
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service.
Titel
SSB-439005 (Last Update: 2020-04-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
14. April 2020 02:00
Text
Titel
SSA-377115 (Last Update: 2020-04-14): SegmentSmack in Linux IP-Stack based Industrial Devices
Veröffentlicht
14. April 2020 02:00
Text
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has ...
Titel
SSA-398519 (Last Update: 2020-04-14): Vulnerabilities in Intel CPUs (November 2019)
Veröffentlicht
14. April 2020 02:00
Text
Intel has published information on vulnerabilities in Intel products in November 2019. In this advisory Siemens only explicitly mentions the vulnerabilities from the "Intel® CPU Security Advisory" and one vulnerability from "Intel® CSME, Intel® SPS, Intel® TXE, Intel® AMT, Intel® PTT and Intel® DAL Advisory" and lists the Siemens IPC ...
Titel
SSA-162506 (Last Update: 2020-04-14): DHCP Client Vulnerability in SIMOTICS CONNECT 400, Desigo PXC/PXM, APOGEE MEC/MBC/PXC, APOGEE PXC Series, and TALON TC Series
Veröffentlicht
14. April 2020 02:00
Text
SIMOTICS CONNECT 400, Desigo (Power PC-based), APOGEE MEC/MBC/PXC and TALON TC products are affected by a DHCP Client vulnerability as initially reported in SSA-434032 for the Mentor Nucleus Networking Module. Siemens has released updates for some products and is working on further updates. For the remaining affected products, Siemens recommends ...
Titel
SSA-473245 (Last Update: 2020-04-14): Denial-of-Service Vulnerability in Profinet Devices
Veröffentlicht
14. April 2020 02:00
Text
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-629512 (Last Update: 2020-04-14): Local Privilege Escalation Vulnerability in TIA Portal
Veröffentlicht
14. April 2020 02:00
Text
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released updates for TIA Portal V15 and V16, and is working on updates for TIA Portal V14. Siemens recommends specific countermeasures as there are currently no ...
Titel
SSA-359303 (Last Update: 2020-04-14): Debug Port in TIM 3V-IE and 4R-IE Family Devices
Veröffentlicht
14. April 2020 02:00
Text
The latest update for TIM 3V-IE family devices and TIM 4R-IE family devices fixes a vulnerability that could allow an unauthenticated attacker with network access to port 17185/udp to gain full control over the device. The devices are only vulnerable if the IP address is configured to 192.168.1.2. Siemens has ...
Titel
SSB-382508 (Last Update: 2020-04-14): ActiveX used in Industrial Products
Veröffentlicht
14. April 2020 02:00
Text
Titel
SSA-270778 (Last Update: 2020-04-14): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software
Veröffentlicht
14. April 2020 02:00
Text
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are ...