SIEMENS CERT
05/13/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to …
SIEMENS CERT
05/13/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
05/13/2025
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
05/13/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. [1] https://security.paloaltonetworks.com/
SIEMENS CERT
05/13/2025
Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user’s session even after logout. Siemens has released new versions for the affected products and recommends to update to …
SIEMENS CERT
05/13/2025
SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller (BMC) that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. Siemens is preparing fix versions and recommends …
SIEMENS CERT
05/13/2025
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the …
SIEMENS CERT
04/17/2025
Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Industrial Edge …