Oktober 2023
Titel
SSA-134651 V1.0: Hard Coded SSH ID in CPCI85 Firmware of SICAM A8000 Devices
Veröffentlicht
10. Oktober 2023 02:00
Text
The CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 contains a hard-coded ID in the SSH authorized_keys configuration file. An attacker with knowledge of the corresponding credential could login to the device via SSH. Only devices with activated debug support are affected. Siemens has released updates for the affected products ...
Titel
SSA-035466 V1.0: Incorrect Permission Assignment in SICAM PAS/PQS
Veröffentlicht
10. Oktober 2023 02:00
Text
SICAM PAS/PQS is affected by insecure permission assignments in application folders that could allow an authenticated local attacker to read and modify configuration data or to escalate privileges. Siemens has prepared a security patch and recommends to run it on affected systems to fix the permissions of the impacted folders. ...
Titel
SSA-203374 V1.1 (Last Update: 2023-10-10): Multiple OpenSSL Vulnerabilities in SCALANCE W1750D Devices
Veröffentlicht
10. Oktober 2023 02:00
Text
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-295483 V1.0: User Enumeration Vulnerability in Mendix Forgot Password Module
Veröffentlicht
10. Oktober 2023 02:00
Text
The Mendix Forgot Password module contains a user enumeration vulnerability that could allow an attacker to retrieve valid users. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-285795 V1.4 (Last Update: 2023-10-10): Denial of Service in OPC-UA in Industrial Products
Veröffentlicht
10. Oktober 2023 02:00
Text
A vulnerability in the underlying third party component OPC UA ANSIC Stack (also called Legacy C-Stack) affects several industrial products. The vulnerability could cause a crash of the component that includes the vulnerable part of the stack. Siemens has released updates for the affected products and recommends to update to ...
Titel
SSA-363107 V1.3 (Last Update: 2023-10-10): An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode
Veröffentlicht
10. Oktober 2023 02:00
Text
A vulnerability was found in SIMATIC WinCC that could allow authenticated attackers to escape the Kiosk Mode. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-524778 V1.0: File Parsing Vulnerabilities in Tecnomatix Plant Simulation
Veröffentlicht
10. Oktober 2023 02:00
Text
Siemens Tecnomatix Plant Simulation contains multiple vulnerabilities that could be triggered when the application reads SPP and IGS files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host ...
Titel
SSA-516174 V1.1 (Last Update: 2023-10-10): Wi-Fi Encryption Bypass Vulnerabilities in SCALANCE W1750D
Veröffentlicht
10. Oktober 2023 02:00
Text
The SCALANCE W1750D device is affected by Wi-Fi encryption bypass vulnerabilities (“Framing Frames”) that could allow an attacker to disclose sensitive information or to steal the victims session. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSB-439005 V5.6 (Last Update: 2023-10-10): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
10. Oktober 2023 02:00
Text
Titel
SSA-413565 V1.3 (Last Update: 2023-10-10): Multiple Vulnerabilities in SCALANCE Products
Veröffentlicht
10. Oktober 2023 02:00
Text
Multiple SCALANCE devices are affected by several vulnerabilities that could allow an attacker to inject code, retrieve data as debug information as well as user CLI passwords or set the CLI to an irresponsive state. Siemens has released updates for the affected products and recommends to update to the latest ...
Titel
SSA-594373 V1.0: Cross-Site-Scripting (XSS) Vulnerability in SINEMA Server V14
Veröffentlicht
10. Oktober 2023 02:00
Text
SINEMA Server V14 improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with SYSTEM privileges on the application server. Siemens recommends to migrate to its successor ...
Titel
SSA-712929 V2.4 (Last Update: 2023-10-10): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
10. Oktober 2023 02:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-711309 V1.1 (Last Update: 2023-10-10): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
10. Oktober 2023 02:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released updates for several affected products and recommends ...
Titel
SSA-250085 V1.3 (Last Update: 2023-10-10): Multiple Vulnerabilities in SINEC NMS and SINEMA Server
Veröffentlicht
10. Oktober 2023 02:00
Text
SINEC NMS and SINEMA Server V14 contain multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. Siemens has released several updates for SINEC NMS and recommends to update to the latest version. Siemens recommends specific ...
Titel
SSA-710008 V1.4 (Last Update: 2023-10-10): Multiple Web Vulnerabilities in SCALANCE Products
Veröffentlicht
10. Oktober 2023 02:00
Text
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update ...
Titel
SSA-770890 V1.0: Path Traversal Vulnerability in the Web Server of CPCI85 Firmware of SICAM A8000 Devices
Veröffentlicht
10. Oktober 2023 02:00
Text
The web server in the CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 is affected by a path traversal vulnerability that could allow an authenticated remote attacker to traverse directories on the system, download arbitrary files and potentially escalate privileges to the administrator role. Siemens has released updates for the ...
Titel
SSA-386812 V1.0: Remote Code Execution Vulnerability in Simcenter Amesim before V2021.1
Veröffentlicht
10. Oktober 2023 02:00
Text
Simcenter Amesim contains a vulnerable SOAP endpoint that could allow an unauthenticated remote attacker to perform DLL injection and execute arbitrary code in the context of the affected application process. Siemens has released an update for Simcenter Amesim and recommends to update to the latest version.
Titel
SSA-647455 V1.0: Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.2 on RUGGEDCOM APE1808 devices
Veröffentlicht
10. Oktober 2023 02:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before V22.6.2. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the ...
Titel
SSA-829656 V1.0: Stack Overflow Vulnerability in Xpedition Layout Browser
Veröffentlicht
10. Oktober 2023 02:00
Text
Siemens Xpedition Layout Browser consists of a stack overflow vulnerability that could be triggered when the application reads a malicious file in PCB format. If a user is tricked to open a malicious file with the affected product, this could lead the application to crash or potentially lead to arbitrary ...
Titel
SSA-843070 V1.0: Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
10. Oktober 2023 02:00
Text
The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to sensitive information disclosure, unauthenticated denial of service or unauthenticated remote code execution. Siemens has released updates for the affected products and recommends to update to the ...
Titel
SSA-240541 V1.1 (Last Update: 2023-10-10): WIBU Systems CodeMeter Heap Buffer Overflow Vulnerability in Industrial Products
Veröffentlicht
10. Oktober 2023 02:00
Text
WIBU Systems published information about a heap buffer overflow vulnerability and associated fix releases of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens industrial products for license management. The vulnerability is described in the section “Vulnerability Classification” below and got assigned the CVE ID CVE-2023-3935. ...
Titel
SSA-784849 V1.0: Direct Memory Access Vulnerabilities in SIMATIC CP Devices
Veröffentlicht
10. Oktober 2023 02:00
Text
Several SIMATIC CP devices contain direct memory access vulnerabilities that could allow an attacker to execute code, access the PROFINET network without restrictions or perform denial of service attacks. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
September 2023
Titel
SSA-357182 V1.0: Local Privilege Escalation Vulnerability in Spectrum Power 7
Veröffentlicht
14. September 2023 02:00
Text
Spectrum Power 7 is affected by a vulnerability that could allow an authenticated local attacker to inject arbitrary code to the update script and escalate privileges. Siemens has released an update for Spectrum Power 7 and recommends to update to the latest version.
Titel
SSA-646240 V1.0: Sensitive Information Disclosure in SIMATIC PCS neo Administration Console
Veröffentlicht
14. September 2023 02:00
Text
The Administration Console of SIMATIC PCS neo leaks Windows admin credentials. An attacker with local Windows access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems. Siemens has released a security patch for the affected products and recommends ...
Titel
SSA-264815 V1.1 (Last Update: 2023-09-12): Type Confusion Vulnerability in OpenSSL X.400 Address Processing in SIMATIC Products
Veröffentlicht
12. September 2023 02:00
Text
Several SIMATIC products are affected by a type confusion vulnerability relating to OpenSSL X.400 address processing (CVE-2023-0286), as disclosed disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for ...