SSA-322980 V1.3 (Last Update: 2024-03-12): Denial of Service Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
12. März 2024 01:00
Text
SIPROTEC 5 devices contain a null pointer dereference vulnerability in the web service. This could allow an attacker to send unauthenticated maliciously crafted http request that could cause denial of service condition of the device. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-576771 V1.0: Multiple Vulnerabilities in SINEMA Remote Connect Server before V3.2
Veröffentlicht
12. März 2024 01:00
Text
SINEMA Remote Connect Server before V3.2 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-225840 V1.0: Vulnerabilities in the Network Communication Stack in Sinteso EN and Cerberus PRO EN Fire Protection Systems
Veröffentlicht
12. März 2024 01:00
Text
Several products used in Sinteso EN and Cerberus PRO EN Fire Protection Systems contain buffer overflow vulnerabilities in the network communication stack. Successful exploitation of the vulnerabilities could allow an unauthenticated attacker, who gained access to the fire protection system network, to execute arbitrary code on the affected products (CVE-2024-22039) ...
Titel
SSA-398330 V1.3 (Last Update: 2024-03-12): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1
Veröffentlicht
12. März 2024 01:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not ...
Titel
SSA-653855 V1.0: Information Disclosure vulnerability in SINEMA Remote Connect Client before V3.1 SP1
Veröffentlicht
12. März 2024 01:00
Text
SINEMA Remote Connect Client before V3.1 SP1 is affected by an information disclosure vulnerability. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-552874 V1.3 (Last Update: 2024-03-12): Denial of Service Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
12. März 2024 01:00
Text
Devices of the SIPROTEC 5 family contain a vulnerability related to secure client-initiated renegotiation. This could allow an unauthenticated attacker to cause a denial of service condition for the duration of the attack. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens ...
Titel
SSA-699386 V1.2 (Last Update: 2024-03-12): Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.5
Veröffentlicht
12. März 2024 01:00
Text
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-792319 V1.0: Missing Read Out Protection in SENTRON 7KM PAC3x20 Devices
Veröffentlicht
12. März 2024 01:00
Text
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the data. Siemens has released new versions for the affected products and recommends to update to the ...
Titel
SSA-770721 V1.0: Multiple Vulnerabilities in SIMATIC RF160B before V2.2
Veröffentlicht
12. März 2024 01:00
Text
SIMATIC RF160B contain multiple vulnerabilities of different types that could allow an attacker to execute arbitrary code within the context of a privileged process. Siemens has released a new version for SIMATIC RF160B and recommends to update to the latest version.
Titel
SSA-832273 V1.0: Multiple Vulnerabilities in Fortigate NGFW on RUGGEDCOM APE1808 devices
Veröffentlicht
12. März 2024 01:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Titel
SSA-918992 V1.0: Unused HTTP Service on SENTRON 3KC ATC6 Ethernet Module
Veröffentlicht
12. März 2024 01:00
Text
SENTRON 3KC ATC6 Expansion Module Ethernet exposes an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet, which could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot. Siemens is preparing fix versions and recommends specific ...
Titel
SSA-871717 V1.1 (Last Update: 2024-03-12): Multiple Vulnerabilities in Polarion ALM
Veröffentlicht
12. März 2024 01:00
Text
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. Siemens is preparing fixes for the vulnerabilities in Polarion 2404 which is expected to be ...
Titel
SSA-968170 V1.2 (Last Update: 2024-03-12): Remote Code Execution Vulnerability in SIMATIC STEP 7 V5.x and Derived Products
Veröffentlicht
12. März 2024 01:00
Text
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to ...
Titel
SSA-943925 V1.1 (Last Update: 2024-03-12): Multiple Vulnerabilities in SINEC NMS before V2.0 SP1
Veröffentlicht
12. März 2024 01:00
Text
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
Titel
SSA-382651 V1.0: File Parsing Vulnerability in Solid Edge before V223.0.11
Veröffentlicht
12. März 2024 01:00
Text
Solid Edge is affected by an out of bounds read vulnerability that could be triggered when the application reads files that contains XT parts. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in ...
Titel
SSA-711309 V1.6 (Last Update: 2024-03-12): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
12. März 2024 01:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released updates for several affected products and recommends ...
Titel
SSA-693975 V1.1 (Last Update: 2024-03-12): Denial-of-Service Vulnerability in the Web Server of Industrial Products
Veröffentlicht
12. März 2024 01:00
Text
A vulnerability in the affected products could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released a new version for SINAMICS S210 (6SL5…) and recommends to update to the latest version. Siemens recommends specific countermeasures for products ...
Titel
SSA-366067 V1.0: Multiple Vulnerabilities in Fortigate NGFW before V7.4.1 on RUGGEDCOM APE1808 devices
Veröffentlicht
12. März 2024 01:00
Text
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Siemens recommends to consult and implement the workarounds provided in Fortinet’s upstream security notifications.
Februar 2024
Titel
SSA-602936 V1.0: Multiple Vulnerabilities in SCALANCE SC-600 Family before V3.1
Veröffentlicht
13. Februar 2024 01:00
Text
SCALANCE SC-600 Family before V3.1 is affected by multiple vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where fixes are not, or not yet available.
Titel
SSA-716164 V1.0: Multiple Vulnerabilities in Scalance W1750D
Veröffentlicht
13. Februar 2024 01:00
Text
The SCALANCE W1750D devices contain multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to sensitive information disclosure, unauthenticated denial of service or unauthenticated remote code execution. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are ...
Titel
SSA-711309 V1.5 (Last Update: 2024-02-13): Denial of Service Vulnerability in the OPC UA Implementations of SIMATIC Products
Veröffentlicht
13. Februar 2024 01:00
Text
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released updates for several affected products and recommends ...
Titel
SSA-647068 V1.0: Ripple20 in SIMATIC RTLS Gateways
Veröffentlicht
13. Februar 2024 01:00
Text
SIMATIC RTLS Gateways are affected by vulnerabilities that were disclosed by JSOF research lab “Ripple20” for the TCP/IP stack. Siemens recommends countermeasures for products where fixes are not, or not yet available.
Titel
SSA-665034 V1.0: Vulnerability in Nozomi Guardian/CMC before 23.3.0 on RUGGEDCOM APE1808 devices
Veröffentlicht
13. Februar 2024 01:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 23.3.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and implement the workarounds ...
Titel
SSA-580228 V1.0: Use of Hard-Coded Credentials Vulnerability in Location Intelligence before V4.3
Veröffentlicht
13. Februar 2024 01:00
Text
Location Intelligence before V4.3 is affected by a Use of Hard-coded Credentials vulnerability that could allow an attacker to obtain full administrative access to the application. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-797296 V1.0: XT File Parsing Vulnerability in Parasolid
Veröffentlicht
13. Februar 2024 01:00
Text
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in XT format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution ...