Dezember 2023
Titel
SSA-794697 V1.5 (Last Update: 2023-12-12): Vulnerabilities in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0
Veröffentlicht
12. Dezember 2023 01:00
Text
Multiple vulnerabilities have been identified in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-831302 V1.3 (Last Update: 2023-12-12): Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0
Veröffentlicht
12. Dezember 2023 01:00
Text
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-887801 V1.0: Information Disclosure Vulnerability in SIMATIC STEP 7 (TIA Portal)
Veröffentlicht
12. Dezember 2023 01:00
Text
Siemens has released a new version of STEP 7 (TIA Portal) that fixes an information disclosure vulnerability. A local attacker could gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
Titel
SSA-844582 V1.0: Electromagnetic Fault Injection in LOGO! V8.3 BM Devices Results in Broken LOGO! V8.3 Product CA
Veröffentlicht
12. Dezember 2023 01:00
Text
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed ...
Titel
SSA-783481 V1.1 (Last Update: 2023-12-12): Denial-of-Service Vulnerability in LOGO! 8 BM
Veröffentlicht
12. Dezember 2023 01:00
Text
A Denial-of-Service vulnerability has been identified in LOGO! 8 BM. This vulnerability could allow an attacker to crash a device, if a user is tricked into loading a malicious project file onto an affected device. The vulnerability is related to the hardware of the product. Siemens has released new hardware ...
Titel
SSA-482757 V1.3 (Last Update: 2023-12-12): Missing Immutable Root of Trust in S7-1500 CPU devices
Veröffentlicht
12. Dezember 2023 01:00
Text
Affected models of the S7-1500 CPU product family do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot ...
Titel
SSA-892915 V1.0: Multiple Denial of Service Vulnerabilities in the Webserver of Industrial Products
Veröffentlicht
12. Dezember 2023 01:00
Text
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver to perform a denial of service attack. Siemens has released a new version for SINAMICS S120 (incl. SIPLUS variants) and recommends to update to the latest version. Siemens recommends specific countermeasures for products ...
Titel
SSA-480095 V1.0: Vulnerabilities in the Web Interface of SICAM Q100 Devices before V2.60
Veröffentlicht
12. Dezember 2023 01:00
Text
The web server of SICAM Q100 devices, versions before V2.60, contains a Cross Site Request Forgery (CSRF) vulnerability and is missing cookie protection flags. This could allow an attacker to perform arbitrary actions on the device on behalf of a legitimate user, or impersonate that user. Siemens has released new ...
Titel
SSA-955858 V1.1 (Last Update: 2023-12-12): Multiple Vulnerabilities in LOGO! 8 BM Devices
Veröffentlicht
12. Dezember 2023 01:00
Text
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. The vulnerabilities are related to the hardware of the product. Siemens has released new hardware versions ...
Titel
SSA-999588 V1.0: Multiple Vulnerabilities in User Management Component (UMC) before V2.11.2
Veröffentlicht
12. Dezember 2023 01:00
Text
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures ...
Titel
SSA-983300 V1.1 (Last Update: 2023-12-12): Vulnerabilities in LOGO! Soft Comfort
Veröffentlicht
12. Dezember 2023 01:00
Text
Two vulnerabilities have been identified in the LOGO! Soft Comfort software. These could allow an attacker to take over a system with the affected software installed. Siemens has released an update for LOGO! Soft Comfort and recommends to update to the latest version.
November 2023
Titel
SSA-264814 V1.2 (Last Update: 2023-11-14): Timing Based Side Channel Vulnerability in the OpenSSL RSA Decryption in SIMATIC Products
Veröffentlicht
14. November 2023 01:00
Text
Several SIMATIC products are affected by a timing based side channel vulnerability in the OpenSSL RSA Decryption (CVE-2023-4304), as disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for ...
Titel
SSA-197270 V1.0: Information Disclosure Vulnerability in Siemens OPC UA Modeling Editor (SiOME)
Veröffentlicht
14. November 2023 01:00
Text
Siemens OPC UA Modeling Editor (SiOME) is affected by an XML external entity (XXE) injection vulnerability that could allow an attacker to interfere with an application’s processing of XML data and read arbitrary files in the system. Siemens has released a new version for Siemens OPC UA Modelling Editor (SiOME) ...
Titel
SSA-292063 V1.0: Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices
Veröffentlicht
14. November 2023 01:00
Text
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before V22.6.3 and 23.1.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and ...
Titel
SSA-268517 V1.0: Code Execution Vulnerability (libwebp CVE-2023-4863) in Mendix Studio Pro
Veröffentlicht
14. November 2023 01:00
Text
Mendix Studio Pro is vulnerable to an out of bounds write vulnerability in the integrated libwebp library (CVE-2023-4863), that could allow an attacker to execute code in the context of a victim user’s system. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-306654 V1.8 (Last Update: 2023-11-14): Insyde BIOS Vulnerabilities in Siemens Industrial Products
Veröffentlicht
14. November 2023 01:00
Text
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-456933 V1.0: Multiple Vulnerabilities in SIMATIC PCS neo before V4.1
Veröffentlicht
14. November 2023 01:00
Text
SIMATIC PCS neo before V4.1 is affected by multiple vulnerabilities. Siemens has released a new version for SIMATIC PCS neo and recommends to update to the latest version.
Titel
SSA-457702 V1.0: Wi-Fi Encryption Bypass Vulnerabilities in SCALANCE W700 Product Family
Veröffentlicht
14. November 2023 01:00
Text
The SCALANCE W700 devices are affected by Wi-Fi encryption bypass vulnerabilities (“Framing Frames”) that could allow an attacker to disclose sensitive information or to steal the victims session. CVE-2022-47522 is divided into 3 different scenarios which are described in the section “Additional Information”. Siemens recommends specific countermeasures for products where ...
Titel
SSB-439005 V5.7 (Last Update: 2023-11-14): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
14. November 2023 01:00
Text
Titel
SSA-407785 V1.1 (Last Update: 2023-11-14): Multiple X_T File Parsing Vulnerabilities in Parasolid and Teamcenter Visualization
Veröffentlicht
14. November 2023 01:00
Text
Parasolid and Teamcenter Visualization are affected by memory corruption vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution or denial of ...
Titel
SSA-478780 V1.0: Multiple WRL File Parsing Vulnerabilities in Tecnomatix Plant Simulation
Veröffentlicht
14. November 2023 01:00
Text
Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code ...
Titel
SSA-625850 V1.0: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family
Veröffentlicht
14. November 2023 01:00
Text
Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS) are affected by multiple vulnerabilities in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of these vulnerabilities could allow remote attackers to execute arbitrary code on the Desigo ...
Titel
SSA-363107 V1.4 (Last Update: 2023-11-14): An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode
Veröffentlicht
14. November 2023 01:00
Text
A vulnerability was found in SIMATIC WinCC that could allow authenticated attackers to escape the Kiosk Mode. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-617233 V1.0: Urgent/11 TCP/IP Stack Vulnerabilities in SIPROTEC 4 7SJ66 Devices
Veröffentlicht
14. November 2023 01:00
Text
SIPROTEC 4 7SJ66 devices are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by nine of the eleven vulnerabilities that are also known as “URGENT/11”. The vulnerabilities could allow an attacker to execute a variety of exploits for the purpose ...
Titel
SSA-309571 V1.9 (Last Update: 2023-11-14): IPU 2021.1 Vulnerabilities in Siemens Industrial Products using Intel CPUs (June 2021)
Veröffentlicht
14. November 2023 01:00
Text
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 ...

Letzte Updates

BOSCH PSIRT
15.01.2025
SIEMENS CERT
17.04.2025
US CERT
01.04.2025
US CERT (ICS)
17.04.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds