SIEMENS CERT
10/14/2025
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the …
SIEMENS CERT
10/14/2025
Multiple Siemens products are affected by a type confusion vulnerability in Google Chrome prior to 138.0.7204.96. This could allow a remote attacker to perform arbitrary code execution via a crafted HTML page. Siemens has released a new version for Industrial Edge App Publisher and recommends to update to the latest …
SIEMENS CERT
10/14/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
10/14/2025
SIMATIC ET 200SP communication processors (CP 1542SP-1, CP 1542SP-1 IRC and CP 1543SP-1, incl. SIPLUS variants) contain an authentication vulnerability that could allow an unauthenticated remote attacker to access the configuration data. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/14/2025
SINEC NMS is affected by SQL injection vulnerability that could allow an authenticated low privileged attacker to exploit by inserting malicious data and achieve privilege escalation. Siemens has released a new version for SINEC NMS and recommends to update to the latest version.
SIEMENS CERT
10/14/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. Customers are advised to consult and implement the workarounds …
SIEMENS CERT
10/14/2025
SIMATIC S7-1200 CPU V1/V2 controllers contain two vulnerabilities that could allow an unauthenticated remote attacker to trigger functions by record and playback of legitimate network communication, or to place the controller in stop/defect state by causing a communications error. Siemens has released new versions for the affected products and recommends …
SIEMENS CERT
10/14/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …