Bulletins

SIEMENS CERT
05/12/2026
Opcenter RDnL is affected by missing authentication in critical function in ‘ActiveMQ Artemis’. An unauthenticated attacker within the adjacent network could use the Core protocol to force a target broker to establish an outbound Core federation connection to an attacker-controlled rogue broker. This could potentially result in availability impacts or …
SIEMENS CERT
05/12/2026
SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where …
SIEMENS CERT
05/12/2026
Siemens Industrial Edge Devices contain an authorization bypass vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
A buffer overflow vulnerability in the User-ID™ Authentication Portal (aka Captive Portal) service of Palo Alto Networks PAN-OS software allows an unauthenticated attacker to execute arbitrary code with root privileges on the PA-Series and VM-Series firewalls by sending specially crafted packets. Siemens is preparing fix versions and recommends countermeasures for …
SIEMENS CERT
05/12/2026
Solid Edge SE2026 before Update 5 is affected by two file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Solid Edge SE2026 …
SIEMENS CERT
05/12/2026
Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/12/2026
The SIPROTEC 5 devices do not use sufficiently random numbers to generate session identifiers. This could facilitate a brute-force attack against a valid session identifier which could allow an unauthenticated remote attacker to hijack a valid user session. The affected session identifiers are only used in a subset of the …
SIEMENS CERT
05/12/2026
The web server in SENTRON 7KT PAC1261 Data Manager Before V2.1.0 contains a request smuggling vulnerability in the Go Project’s net/http package that could allow an attacker to retrieve authorization tokens that can be used to gain administrative control over the device. Siemens has released a new version for SENTRON …