August 2024
Titel
SSA-686975 V1.5 (Last Update: 2024-08-13): IPU 2022.3 Vulnerabilities in Siemens Industrial Products using Intel CPUs
Veröffentlicht
13. August 2024 02:00
Text
Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update (“2022.3 IPU – BIOS Advisory” Intel-SA-00688). Siemens is preparing updates and recommends specific countermeasures for products ...
Titel
SSA-856475 V1.0: X_T File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go
Veröffentlicht
13. August 2024 02:00
Text
Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform ...
Titel
SSA-921449 V1.0: Plaintext Storage of a Password Vulnerability in LOGO! V8.3 BM Devices
Veröffentlicht
13. August 2024 02:00
Text
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set passwords from an embedded storage IC. Siemens has released new hardware versions with the LOGO! V8.4 BM product family for ...
Titel
SSA-068047 V1.1 (Last Update: 2024-08-13): Multiple Vulnerabilities in SCALANCE M-800 Family Before V7.2.2
Veröffentlicht
13. August 2024 02:00
Text
SCALANCE M-800 family before V7.2.2 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-999588 V1.4 (Last Update: 2024-08-13): Multiple Vulnerabilities in User Management Component (UMC) Before V2.11.2
Veröffentlicht
13. August 2024 02:00
Text
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes ...
Titel
SSA-716317 V1.0: Multiple Vulnerability in SINEC Traffic Analyzer Before V2.0
Veröffentlicht
13. August 2024 02:00
Text
SINEC Traffic Analyzer before V2.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version.
Titel
SSA-720392 V1.0: Multiple Vulnerabilities in Third-Party Components in Location Intelligence Before V4.4
Veröffentlicht
13. August 2024 02:00
Text
Location Intelligence before V4.4 is affected by multiple vulnerabilities that could allow an attacker in an on-path position to read and modify data passed over the connection between legitimate clients and the affected product or brute force user passwords. Siemens has released a new version for Location Intelligence family and ...
Titel
SSA-659443 V1.0: Local Code Execution Vulnerabilities in COMOS Before V10.5
Veröffentlicht
13. August 2024 02:00
Text
COMOS before V10.5 is affected by two local code execution vulnerabilities in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.
Titel
SSA-981975 V1.3 (Last Update: 2024-08-13): Information Disclosure Vulnerability in Intel-CPUs (CVE-2022-40982) Impacting SIMATIC IPCs
Veröffentlicht
13. August 2024 02:00
Text
Several Intel-CPU based SIMATIC IPCs are affected by an information exposure vulnerability (CVE-2022-40982) in the CPU that could allow an authenticated local user to potentially read other users’ data [1]. The issue is also known as “Gather Data Sampling” (GDS) or Downfall Attacks. For details refer to the chapter “Additional ...
Titel
SSA-857368 V1.0: Multiple Vulnerabilities in Omnivise T3000
Veröffentlicht
2. August 2024 02:00
Text
Omnivise T3000 contains multiple vulnerabilities that could allow an attacker to escalate privileges. Siemens Energy has released patches for several affected products and recommends to apply the patches. Siemens Energy is preparing further fixes for versions still under maintenance and recommends countermeasures for products where fixes are not, or not ...
Juli 2024
Titel
SSA-723487 V1.1 (Last Update: 2024-07-22): RADIUS Protocol Susceptible to Forgery Attacks (CVE-2024-3596) - Impact to SCALANCE, RUGGEDCOM and Related Products
Veröffentlicht
22. Juli 2024 02:00
Text
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to ...
Titel
SSA-071402 V1.0: Multiple Vulnerabilities in SICAM Products
Veröffentlicht
22. Juli 2024 02:00
Text
Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: SICAM A8000 Device firmware CPCI85 for CP-8031/CP-8050 SICAM EGS Device firmware CPCI85 SICAM 8 Software Solution SICORE Siemens has released new firmware versions for the ...
Titel
SSA-265688 V1.2 (Last Update: 2024-07-09): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1
Veröffentlicht
9. Juli 2024 02:00
Text
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
Titel
SSA-293562 V3.5 (Last Update: 2024-07-09): Denial of Service Vulnerabilities in PROFINET DCP Implementation of Industrial Products
Veröffentlicht
9. Juli 2024 02:00
Text
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has ...
Titel
SSA-750274 V1.1 (Last Update: 2024-07-09): Impact of CVE-2024-3400 on RUGGEDCOM APE1808 devices configured with Palo Alto Networks Virtual NGFW
Veröffentlicht
9. Juli 2024 02:00
Text
Palo Alto Networks has published [1] information on CVE-2024-3400 in PAN-OS. This advisory addresses Siemens Industrial products affected by this vulnerability. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to consult and ...
Titel
SSA-337522 V1.1 (Last Update: 2024-07-09): Multiple Vulnerabilities in TIM 1531 IRC before V2.4.8
Veröffentlicht
9. Juli 2024 02:00
Text
Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-750499 V1.0: Weak Encryption Vulnerability in SIPROTEC 5 Devices
Veröffentlicht
9. Juli 2024 02:00
Text
The SIPROTEC 5 devices are supporting weak encryption. This could allow an unauthorized attacker in a man-in-the-middle position to read any data passed over the connection between legitimate clients and the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. ...
Titel
SSA-170375 V1.0: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9
Veröffentlicht
9. Juli 2024 02:00
Text
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
Titel
SSA-313039 V1.0: Deserialization Vulnerability in STEP 7 Safety before V19
Veröffentlicht
9. Juli 2024 02:00
Text
Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released a new version for SIMATIC STEP 7 Safety V18 and recommends to update to the latest ...
Titel
SSA-753746 V1.3 (Last Update: 2024-07-09): Denial of Service Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products
Veröffentlicht
9. Juli 2024 02:00
Text
Two null point dereference vulnerabilities affect multiple SIMATIC software products. These could allow an attacker to cause a persistent denial of service condition in the RPC Server of these products. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Titel
SSA-160243 V1.1 (Last Update: 2024-07-09): Multiple Vulnerabilities in SINEC NMS before V2.0
Veröffentlicht
9. Juli 2024 02:00
Text
SINEC NMS before V2.0 is affected by a code injection and a stored cross-site scripting vulnerability. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
Titel
SSA-088132 V1.0: Denial of Service Vulnerability in the OPC UA Server Implementations of Several Industrial Products
Veröffentlicht
9. Juli 2024 02:00
Text
Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in several industrial products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the OPC ...
Titel
SSA-364175 V1.0: Multiple Vulnerabilities in Palo Alto Networks Virtual NGFW on RUGGEDCOM APE1808 devices
Veröffentlicht
9. Juli 2024 02:00
Text
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds ...
Titel
SSA-824889 V1.0: XML File Parsing Vulnerabilities in JT Open and PLM XML SDK
Veröffentlicht
9. Juli 2024 02:00
Text
JT Open Toolkit and PLM XML SDK are affected by stack buffer overflow and null pointer dereference vulnerabilities that could be triggered while parsing XML file. If a user is tricked to open a malicious XML file with any of the affected products, this could cause the application to crash ...
Titel
SSA-780073 V2.4 (Last Update: 2024-07-09): Denial of Service Vulnerability in PROFINET Devices via DCE-RPC Packets
Veröffentlicht
9. Juli 2024 02:00
Text
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial of service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released new versions for several affected products and recommends to update to the latest versions. ...

Letzte Updates

BOSCH PSIRT
14.08.2025
SIEMENS CERT
16.09.2025
US CERT
25.08.2025
US CERT (ICS)
16.09.2025

Nach Quelle

Archiv

2025
2024
2023
2022
2021
2020
2019
2018
2017

Feeds